ASTM E547 PDF

| | 0 Comments

based on specific design pressures (DP). ▫ Water penetration resistance (ASTM E and ASTM E). ▫ Uniform load deflection test (ASTM. ASTM International E Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Wall by Cyclic Static Air Pressure. ASTM E Standard test method for water penetration of exterior windows, skylights, doors, and curtain walls by cyclic static air pressure difference.

Author: Vulabar Nesida
Country: Belize
Language: English (Spanish)
Genre: Politics
Published (Last): 17 August 2008
Pages: 480
PDF File Size: 14.86 Mb
ePub File Size: 5.74 Mb
ISBN: 652-8-85730-189-4
Downloads: 37014
Price: Free* [*Free Regsitration Required]
Uploader: Mezigor

This allows us to not only properly test fenestrations on new construction projects, but also pinpoint the cause of any test failures and provide accurate recommendations to achieve successful testing results. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

I also detailed the value of assembly testing which evaluates the complex details in real building walls versus material testing that evaluates a specific astmm without linkage to the wall geometry and the different substrate conditions in the wall.

Professional services based on accurate information that helps you or your company make the right decision regarding your project f547 asset.

Water that penetrates the assembly, but does not result in a failure as defined herein, may have adverse effects on the performance of contained materials such as sealants and insulating or laminated glass. The water asttm system has astk spaced on a grid to deliver water so that the test specimen is wet uniformly, including those areas vulnerable to water penetration.

In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment.

  2SB546A DATASHEET PDF

In my last blog, I focused on a long standing and very useful laboratory test used to measure water penetration: The E test, like E, provides the details of the instrumentation e5477 to ASTM E to create a pressure difference across a multitude of building assemblies during the calibrated water spray minimum rate of 3. Historical Version s – view previous versions of standard. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water.

The test-pressure difference or differences at which water penetration is to be determined, unless otherwise specified, asm be Aatm 2.

astm-e | Building Diagnostics Group

asym Most generic specifications call for a minimum testing pressure of 6. In my last blog I listed the steps for the E test and in this blog I have left kept those steps but in bold font for comparison. Failures during quality assurance new construction testing can result in unnecessary delays that impact your bottom line. This test method does not identify unobservable liquid water which may penetrate into the test d547. Building Diagnostics Group, Inc.

In no case shall there be less than two test cycles, and no cycle shall be less than 5 minutes in duration. Our field consultants are properly trained and knowledgeable of all testing standards. These factors should be r547 considered prior to specifying the test pressure difference to be used.

ASTM E 547

The list below shows what we have discussed so far and the next steps. Some designs are more sensitive than others to this upward moving water. MISSION Professional services based on accurate information that helps you or your company make the right decision regarding your project or asset. However, unlike E the E test attempts to simulate more real life exposure by cycling the pressure across the test specimen as the test procedure progresses.

  AL MUNJID ARABIC DICTIONARY PDF

The ASTM E testing is performed by applying water to the exterior of the test specimen while lowering the pressure inside by means of an air chamber built on the inside or opposite side of the test specimen. Some designs are more sensitive than others to this upward moving water. Blog Building Wall Assemblies: See the summary for E in this link: These factors should be fully considered prior to specifying the test pressure difference to be used.

ASTM E547 – 00(2016)

If you are looking for a reputable second or third-party testing company to perform accurate professional testing, provide concise reports, and help you through the entire process, contact BDG today. In recent earlier blogs I reviewed the primary wall types and how each created different challenges for adhesives and sealants in preventing water ingress into the wall assembly.

In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment.

The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. These methods are often used both for determining the cause of existing building air leakage and for confirming the adequacy of newly constructed wall designs.

The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.

BDG utilizes professional testing equipment that is calibrated to each specific testing standard for accurate results.